Updated: Apr-04-2021

General Information

Type of service provider
Testing laboratory
Physical postal address

Jl. Selabintana
Sukabumi
Indonesia

Phone number
+62 266 225211
E-mail
labuji.bbpbats [at] gmail.com
labuji_bbpbats [at] yahoo.com
Has the laboratory been accredited in any scopes?
Yes
Scopes of Accreditation
Biology, Chemical and Physical
Accreditation body
National Accreditation Body of Indonesia (KAN)
No: LP-1117 IDN
Does the laboratory have other sites?
No
Other locations

Indonesia

Personnel

Chief Executive Officer (CEO) / Head of Organization

CEO Name
Endang Mudjiutami
CEO Phone
CEO E-mail
mudjiutami [at] yahoo.com

Total laboratory personnel

Total laboratory personnel
21
Male laboratory personnel
9
Female laboratory personnel
12

Technical personnel

Technical personnel total
13
Male technical personnel
5
Female technical personnel
8

Technical Information

Testing

Laboratory services offered
Biological
Chemical
Water / food
Scope of services offered
Test object or product tested or matrices
Water, Feed, Fish and Prawn
Test parameter/ properties measured
- Trichodina sp, Ichtiophtirius multiphilis, Aeromonas hydrophila, Vibrio sp, KHV, E.Colli, Salmonella
- Temp, turbidity, pH
- Dissolve Oksigen, Carbondioxide, Alkalinity
- Ammonium, Nitrite, Phosphate
- CD, Pb, Hg
- Moisture, Ash
- Total Fat
- Crude Fiber
-Chlorampenicol, AOZ, AMOZ, Tetracycline, Oxytetracycline, Diethylstilbestrol, Total Aflatoxin
Type of test/ instrumentation used
- Microscopy
- Water quality testing
- Sektrophotometry
- AAS
- Gravimetry
- Fat Extractor
- Fibertherm
- ELISA
- LC/MSMS
Methods
Laboratory-developed method
Indonesian standard No 7303:2015
Laboratory-developed method
Indonesian standard No 7547:2009,
No 2332.1:2015
No 6579:2015
APHA 21nd edition, 2550,200
APHA 21nd edition, 2130b,2005
APHA 21nd edition, 2320,2005
Indonesian standard No 06-6989.14:2004
Indonesian standard No 066989.
APHA 21nd edition, 4500-co2.c,2005,

Indonesian standard No Indonesian standard No 06-6989.9:2004
APHA 21nd eddition 4500-p.c,2005
AOAC 999.10,2005 chapter 9
AOAC 999.11,2005 chapter 9
AOAC 779.15,2005 chapter 9
Indonesian standard No 2354-1:2010
Indonesian standard No 2354-2:2015
Indonesian standard No 2354-13:2017
Indinesian standard No 01-2891-1992

III.NR.10
III.NR.12
III.NR.14
III.NR.15
III.NR.16
III.NR.17
III.NR.18
Accreditation status
Yes
Does the laboratory conduct sampling, upon request of the client, of products to be tested?
No

Proficiency Testing

Does the lab participate in proficiency testing for accredited scopes
Yes
Does the lab participate in proficiency testing for non-accredited scopes
Yes
PT Scheme details
Sample provided from Accredited PT Provider based on ISO/IEC 17043
Does the laboratory sub-contract testing work to other laboratories?
Yes
Outsourced services
No equipment nor accredited method available
Documented policies, procedures and records for the qualification, assessing and monitoring of all outsourced services providers
Yes
Please specify in which type of document all these aspects are covered
Stated in Quality manual and SOP

Quality Control / Quality Management

Does the lab operate an internal quality control (QC) system to ensure quality of test results?
Yes
Does the lab operate a management system (or Quality Management System) for assuring the quality of results?
Yes
Is the system documented in a Quality Manual?
Yes