General Information

Type of service provider
Calibration laboratory
Physical postal address

Abidjan
Côte d’Ivoire

Phone number
+ 225 43 11 01 01/ 43 11 02 02/ 43 11 03 03
E-mail
infoline [at] lanema.ci
Has the laboratory been accredited in any scopes?
Yes
Scopes of Accreditation
Chemical Analysis - Environment
Initial audit in temperature metrology on 11 and 12 June 2019.
Accreditation body
TUNAC N° 1-0067; SOAC (Temperature)
Does the laboratory have other sites?
Yes
Other locations

Abidjan
Côte d’Ivoire

Personnel

Chief Executive Officer (CEO) / Head of Organization

CEO Name
Yapi Clément Aie
CEO Phone
CEO E-mail
clementaie [at] yahoo.fr

Technical Information

Fields of Metrology

DC and low frequency electrical
Force
Mass
Pressure
Temperature
Volume and density
Scope of calibration services offered
Calibration object
DC and low frequency electricity
Quantity/ Property
Resistance
Procedure reference
IEC Standards and Guides COFRAC and EURAMET
Range/ Limit
5KΩ -1TΩ / 5TΩ - 100TΩ
CMC
Not rated
Accreditation status
No
Calibration object
DC and low frequency electricity
Quantity/ Property
Capacity
Procedure reference
IEC Standards and Guides COFRAC and EURAMET
Range/ Limit
220pF to 110mF
CMC
Not rated
Accreditation status
No
Calibration object
DC and low frequency electricity
Quantity/ Property
Voltage (A/D)
Procedure reference
IEC Standards and Guides COFRAC and EURAMET
Range/ Limit
1mV à 1020 V
CMC
Not rated
Accreditation status
No
Calibration object
DC and low frequency electricity
Quantity/ Property
Frequency
Procedure reference
IEC Standards and Guides COFRAC and EURAMET
Range/ Limit
3Hz to 1MHz
CMC
Not rated
Accreditation status
No
Calibration object
DC and low frequency electricity
Quantity/ Property
Intensity (A/D)
Procedure reference
IEC Standards and Guides COFRAC and EURAMET
Range/ Limit
29.00 microA to 25A + 50 turns toroid
Accreditation status
No
Calibration object
Torque wrenches
Quantity/ Property
Force - torque
Procedure reference
No acquired standard
Range/ Limit
From 0 to 5000 N.m
CMC
Not started yet
Accreditation status
No
Calibration object
Work masses
Quantity/ Property
Mass
Procedure reference
Gravimetric measurement against the reference mass
Range/ Limit
from 1 g to 20 kg
CMC
From 5 micro g to 5 mg
Accreditation status
No
Calibration object
Non-Automatic Weighing Instruments
Quantity/ Property
Weighing
Procedure reference
Eccentricity, accuracy, fidelity tests
Range/ Limit
0 to 60 kg
CMC
Not rated
Accreditation status
No
Calibration object
Pressure gauges
Quantity/ Property
Pressure
Range/ Limit
0 to 1250 bar
Accreditation status
No
Calibration object
Thermostatic chamber
Quantity/ Property
Temperature
Procedure reference
9-point measurement by comparison with temperature probes
Range/ Limit
- 20°C to 130°C
CMC
0.24°C
Accreditation status
No
Calibration object
Temperature chain
Quantity/ Property
Temperature
Procedure reference
Calibration by comparison to a reference chain
Range/ Limit
- 20°C to 600°C
CMC
From 0.11°C to 0.83°C
Accreditation status
No
Calibration object
Micropipette
Quantity/ Property
Volume
Procedure reference
GUM & Eurachem method.
- Standard ISO8655-1-6
- Technical Report - ISO/TR 20461:2000
- DKD R81
- COFRAC LAB GTA 90
Range/ Limit
1 µl – 10 µl
100 µl – 10 ml
Accreditation status
No
Calibration object
Pipette
Quantity/ Property
Volume
Procedure reference
GUM & Eurachem method.
- Standard ISO8655-1-6
- Technical Report - ISO/TR 20461:2000
- DKD R81
- COFRAC LAB GTA 90
Range/ Limit
1000 ml – 2500 ml
CMC
± 0,020 ml
Accreditation status
No
Calibration object
Vials
Quantity/ Property
Volume
Procedure reference
GUM & Eurachem method.
- Standard ISO8655-1-6
- Technical Report - ISO/TR 20461:2000
- DKD R81
- COFRAC LAB GTA 90
Range/ Limit
From 5 ml to 20L
CMC
From ± 0,025 ml to ± 4,8 ml
Accreditation status
No
Uncertainty of measurements reports
Yes
Statement identifying how the measurements are metrologically traceable
Yes

How does the laboratory ensure international traceability of its measurements standards?

Through calibration certificates issues by an accredited national laboratory
no
Through calibration certificates issues by an accredited overseas laboratory
Yes
Does the lab participate in any inter- laboratory comparison?
Yes
Please provide details about the scheme
Bilateral Inter-laboratory Comparison with the CNCC of Tunisia in temperature.
WAEMU mass Inter-laboratory Comparison in 2017.
Inter-laboratory comparison circuits are difficult to obtain.
Does the laboratory sub-contract calibration work to other laboratories?
No

Quality Control / Quality Management

Does the lab operate an internal quality control (QC) system to ensure quality of measurement?
Yes
Does the lab operate a management system (or Quality Management System) for assuring the quality of calibrations?
Yes
Is the system documented in a Quality Manual?
Yes