General Information
Type of service provider
Calibration laboratory
Physical postal address
NO 5 APAGODO STREET, OFF ADA GEORGE ROAD, PORT HARCOURT
Rivers State
Nigeria
Phone number
+234 (0)9070042443
E-mail
equiries [at] engineeringautomation-ng.com
contact [at] eatlng.com
Website
Legal Status
Private
Has the laboratory been accredited in any scopes?
Yes
Scopes of Accreditation
i. Electrical- Low voltage
• 0 – 1000 Volts DC Voltage, 1mV – 1000 Volts AC (rms) Voltage
• 0 – 1000 Amperes DC Current, 500 µA – 1000 Amperes AC (rms) Current
• 10 Ω – 1 GΩ Decade Resistance Values
• 10 Ω – 40 kΩ Simulated Resistance/PT100 Simulation
ii. Temperature (- 40 °C to 140 °C)
iii. Pressure (0 - 10,000 Psi)
• 0 – 1000 Volts DC Voltage, 1mV – 1000 Volts AC (rms) Voltage
• 0 – 1000 Amperes DC Current, 500 µA – 1000 Amperes AC (rms) Current
• 10 Ω – 1 GΩ Decade Resistance Values
• 10 Ω – 40 kΩ Simulated Resistance/PT100 Simulation
ii. Temperature (- 40 °C to 140 °C)
iii. Pressure (0 - 10,000 Psi)
Accreditation body
Accreditation Final Assessment has been completed by the Nigeria National Accreditation Service (NiNAS)
Does the laboratory have other sites?
No
Personnel
Chief Executive Officer (CEO) / Head of Organization
CEO Name
Emmanuel Okon (FNATE, FIOGR, MMSN)
CEO Phone
CEO E-mail
Emmanuel.okon [at] engineeringautomation-ng.com
Total laboratory personnel
Total laboratory personnel
7
Male laboratory personnel
5
Female laboratory personnel
2
Technical personnel
Technical personnel total
6
Male technical personnel
5
Female technical personnel
1
Technical Information
Fields of Metrology
DC and low frequency electrical
Pressure
Temperature
Scope of calibration services offered
Calibration object
Electrical Standards
Quantity/ Property
Electrical
Procedure reference
EURAMET/Cg – 15/V.01 (Guidelines on Calibration of Digital Multimeters).
Range/ Limit
0– 1000 Volts DC Voltage,
1mV – 1000 Volts AC (rms) Voltage
0 – 1000 Amperes DC Current,
500 µA – 1000 Amperes AC (rms) Current
10 Ω – 1 GΩ Decade Resistance Values
10 Ω – 40 kΩ Simulated Resistance/PT100 Simulation
1mV – 1000 Volts AC (rms) Voltage
0 – 1000 Amperes DC Current,
500 µA – 1000 Amperes AC (rms) Current
10 Ω – 1 GΩ Decade Resistance Values
10 Ω – 40 kΩ Simulated Resistance/PT100 Simulation
CMC
0– 1000 Volts DC Voltage,
1mV – 1000 Volts AC
0 – 1000 Amperes DC
500 µA – 1000 Amperes AC
10 Ω – 1 GΩ Decade Resistance
10 Ω – 40 kΩ Simulated Resistance/PT100
1mV – 1000 Volts AC
0 – 1000 Amperes DC
500 µA – 1000 Amperes AC
10 Ω – 1 GΩ Decade Resistance
10 Ω – 40 kΩ Simulated Resistance/PT100
Accreditation status
Yes
Calibration object
Temperature Standards
Quantity/ Property
Temperature
Procedure reference
NIST Handbook
105 – 6 (Specifications and Tolerances for Thermometers),
Procedure for Calibration and Certification of Thermometers (EATL/E&I/PR/033)
105 – 6 (Specifications and Tolerances for Thermometers),
Procedure for Calibration and Certification of Thermometers (EATL/E&I/PR/033)
Range/ Limit
-40 °C to 140 °C
CMC
-10 °C to 140 °C
Accreditation status
Yes
Calibration object
Pressure Standards
Quantity/ Property
Pressure
Procedure reference
BS EN 837-1:1998,
Pressure Gauge Calibration & Adjustment Procedure
(EATL/E&I/PR/005)
Pressure Gauge Calibration & Adjustment Procedure
(EATL/E&I/PR/005)
Range/ Limit
0 to 10,000 psi
CMC
0 – 10,000 psi
Accreditation status
Yes
Uncertainty of measurements reports
Yes
How does the laboratory ensure international traceability of its measurements standards?
Through calibration certificates issues by an accredited national laboratory
no
Through calibration certificates issues by an accredited overseas laboratory
Yes
Does the lab participate in any inter- laboratory comparison?
Yes
Please provide details about the scheme
Interlaboratory comparison was conducted with Selfa Nigeria Limited. The scope covered was Low Voltage Electrical, Temperature and Pressure. Artifacts were calibrated by each lab and the results analyzed using statistical means.
Does the laboratory sub-contract calibration work to other laboratories?
No
Quality Control / Quality Management
Does the lab operate an internal quality control (QC) system to ensure quality of measurement?
Yes
Does the lab operate a management system (or Quality Management System) for assuring the quality of calibrations?
Yes
Is the system documented in a Quality Manual?
Yes