General Information
Type of service provider
Testing laboratory
Physical postal address
Jl. Laksamana Malahayati Km.16 Ujung Batee
Banda Aceh
Indonesia
E-mail
labbpbapub [at] gmail.com
tu.bbapub [at] gmail.com
Legal Status
Public
Has the laboratory been accredited in any scopes?
Yes
Scopes of Accreditation
Testing for fish and shrimp
Accreditation body
National Accreditation Body of Indonesia (KAN), accreditation number LP-1351-IDN
Does the laboratory have other sites?
No
Personnel
Chief Executive Officer (CEO) / Head of Organization
CEO Name
M. Tahang
CEO Phone
CEO E-mail
tahang.madc [at] gmail.com
Total laboratory personnel
Total laboratory personnel
7
Male laboratory personnel
3
Female laboratory personnel
4
Technical personnel
Technical personnel total
6
Male technical personnel
2
Female technical personnel
4
Technical Information
Testing
Laboratory services offered
Biological
Water / food
Environmental
Scope of services offered
Test object or product tested or matrices
fish; shrimp
Test parameter/ properties measured
Viral Nervous Necrosis;
White Spot Syndrome Virus;
Infectious Hypodermal and Hematopoietic Necrosis Virus
White Spot Syndrome Virus;
Infectious Hypodermal and Hematopoietic Necrosis Virus
Type of test/ instrumentation used
Biology molecular (conventional PCR)
Methods
Indonesian standard 7546.1:2015, 8094.2:2016, 7912.2:2016
Accreditation status
Yes
Test object or product tested or matrices
Fish; shrimp
Test parameter/ properties measured
Viral disease
Type of test/ instrumentation used
Histopathology
Methods
Indonesian standard 7662.2:2011, 7304:2009
Accreditation status
No
Test object or product tested or matrices
Aquaculture water
Test parameter/ properties measured
Ammoniac, nitrate, nitrite, phosphate, Fe, alkalinity, Total organic matter, chlorine, temperature, turbidity, Salinity
Type of test/ instrumentation used
Colorimetry,
Titrimetric,
Spectrophotometry
Titrimetric,
Spectrophotometry
Methods
Indonesian standard 19-6964.3-2003
06.6989-2004
06-6989.23-2005
06-6989.31-2005
Laboratory methods: SPO/LINGK/009/BPBAPUB,
SPO/LINGK/011/BPBAPUB,
SPO/LINGK/012/BPBAPUB, SPO/LINGK/017/BPBAPUB,
SPO/LINGK/018/BPBAPUB,
SPO/LINGK/021/BPBAPUB,
SPO/LINGK/006/BPBAPUB,
SPO/LINGK/007/BPBAPUB
06.6989-2004
06-6989.23-2005
06-6989.31-2005
Laboratory methods: SPO/LINGK/009/BPBAPUB,
SPO/LINGK/011/BPBAPUB,
SPO/LINGK/012/BPBAPUB, SPO/LINGK/017/BPBAPUB,
SPO/LINGK/018/BPBAPUB,
SPO/LINGK/021/BPBAPUB,
SPO/LINGK/006/BPBAPUB,
SPO/LINGK/007/BPBAPUB
Accreditation status
No
Test object or product tested or matrices
Fish, shrimp
Test parameter/ properties measured
Monodon Baculovirus,
Acute Hepatopancreatic Necrosis Diseases,
Irido virus,
Tilapia Lake Virus,
Macrobrachium rosenbergii Nodavirus
Acute Hepatopancreatic Necrosis Diseases,
Irido virus,
Tilapia Lake Virus,
Macrobrachium rosenbergii Nodavirus
Type of test/ instrumentation used
Biology molecular (conventional PCR)
Methods
Indonesia standard: 7824:2013.
OIE methods:
OIE chapter 2.2.1
OIE chapter 2.2.6
Laboratory methods:
BUSKIPM 2015
BUSKIPM 2017
OIE methods:
OIE chapter 2.2.1
OIE chapter 2.2.6
Laboratory methods:
BUSKIPM 2015
BUSKIPM 2017
Accreditation status
No
Test object or product tested or matrices
Fish feed
Test parameter/ properties measured
moisture content, ash content, crude protein, crude fat, crude fiber
Type of test/ instrumentation used
Gravimetric, Dumas methods, Soxhletasi gravimetry
Methods
Indonesian standard:
01-2354.2-2006
01-2354.1-2006
Laboratory methods:
method Dumatherm Gerhardt (protein);
Soxtherm Gerhardt (fat);
Fibertherm Gerhardt (fiber)
01-2354.2-2006
01-2354.1-2006
Laboratory methods:
method Dumatherm Gerhardt (protein);
Soxtherm Gerhardt (fat);
Fibertherm Gerhardt (fiber)
Accreditation status
No
Does the laboratory conduct sampling, upon request of the client, of products to be tested?
Yes
Proficiency Testing
Does the lab participate in proficiency testing for accredited scopes
No
Does the lab participate in proficiency testing for non-accredited scopes
No
Inter-laboratory comparison
Yes
Interlaboratory comparison scheme
Laboratory BPBAP UB sends testing samples to other testing laboratories
Does the laboratory sub-contract testing work to other laboratories?
No
Quality Control / Quality Management
Does the lab operate an internal quality control (QC) system to ensure quality of test results?
Yes
Does the lab operate a management system (or Quality Management System) for assuring the quality of results?
Yes
Is the system documented in a Quality Manual?
Yes